Symptoms
-
Advanced Monitoring shows the error:
PLESK_INFO: login.OAuthLogin(missing saved state)
-
The following errors could be found in
/var/log/grafana/grafana.log
:CONFIG_TEXT: lvl=eror msg="Failed to look up user based on cookie" logger=context error="user token not found"
Cause
This issue was reported to Grafana vendor.
Follow the article to be notified when the bug is fixed - the article will be updated accordingly.
Resolution
As a workaround, delete browser cookies ("grafana_session" cookie should be removed).
If the issue still persists, check the article [BUG] Advanced Monitoring showing "login.OAuthLogin(missing saved state)"