Plesk with watchdog hangs at reboot/shutdown

Refers to:

  • Plesk 11.5 for Linux

Created:

2016-11-16 13:11:05 UTC

Modified:

2016-12-21 20:08:22 UTC

0

Was this article helpful?


Have more questions?

Submit a request

Plesk with watchdog hangs at reboot/shutdown

Symptoms

The server will not restart with the watchdog module installed: the system crashes while rebooting ( shutdown -r now ). The server can only be restarted via a forced shutdown.

Cause

The issue is caused by an incorrect watchdog init script, /etc/init/psa-monit.conf .

This is a software issue. Its ID is PPPM-822 . The issue was fixed in Parallels Plesk Panel 11.5.30 MU#15 .

Resolution

Install the latest Micro-Updates:

#/usr/local/psa/admin/sbin/autoinstaller --select-release-current --install-component base --reinstall-patch
Have more questions? Submit a request
Please sign in to leave a comment.