Health monitor stops suddenly

Created:

2016-11-16 13:04:34 UTC

Modified:

2017-04-24 11:58:30 UTC

0

Was this article helpful?


Have more questions?

Submit a request

Health monitor stops suddenly

Applicable to:

  • Plesk Onyx for Windows
  • Plesk 11.5 for Linux
  • Plesk 12.0 for Linux

Symptoms

Health monitor works unstable and stops suddenly.

Cause

It is software issue PPPM-1097.

Resolution

There are a custom fixes for Debian 6 (x64) and Ubuntu 12.04 (x64).

For other OS'es you may implement a work around:

Create a cron task which will start sw-collectd service if it is stopped. For example, by adding the following line to '/etc/crontab' :

*/10 * * * * root [ ! -f '/var/run/sw-collectd.pid' ] && /etc/init.d/sw-collectd start