Symptoms

Odin Premium Antivirus installed with EZ Application Template cannot be started.

Interface binding error (/var/drweb/run/.daemon - Address already in use)!
Interface binding error (127.0.0.1:3000 - Address already in use)!

Cause

This is a software issue with internal ID PPPM-2463 . It is fixed in Plesk 12.5

Resolution

  1. Check if there is running drwebd.real process:

    # netstat -tulpn | grep 3000   
    tcp 0 0 127.0.0.1:3000 0.0.0.0:* LISTEN 2057/drwebd.real
  2. Kill this process

    #killall drwebd.real
  3. Start DrWeb service

    #/etc/init.d/drwebd start