Applicable to:
- Plesk for Windows
Symptoms
-
The Plesk UI is not accessible with the error:
CONFIG_TEXT: 500 Plesk\Exception\Database
-
It is not possible to start the Plesk SQL Server service with the error:
CONFIG_TEXT: Error 1053: The service did not respond to the start or control request in a timely fashion.
-
The next error can be found in the Event Viewer or the MySQL log file:
CONFIG_TEXT: [ERROR] Can't start server: Bind on TCP/IP port. Got error: 10048: Only one usage of each socket address (protocol/network address/port) is normally permitted.
[ERROR] Do you already have another mysqld server running on port: 3306 ?
[ERROR] Aborting
Cause
The Plesk SQL Server service is configured incorrectly: the Path to executable parameter in the Plesk SQL Server configuration does not contain the data about the configuration file.
Resolution
-
Connect to the server via RDP
-
Determine the path to Plesk directory:
C:\> SET | findstr plesk_dir
-
Use the
plesk_dir
from the output of the previous command to set the correct value for Path to executable parameter. E.g. if the output was as follows:C:\> plesk_dir=C:\Program Files (x86)\Plesk\
, use the following command:
C:\> sc config PleskSQLServer binPath= "\"C:\Program Files (x86)\Plesk\MySQL\bin\mysqld.exe\" --defaults-file=\"C:\Program Files (x86)\Plesk\MySQL\my.ini\" PleskSQLServer"